Trilithic

Seeker Lite²

Leakage Detector

Seeker Lite²

Includes the following:

  • Leakage Detector with Internal Antenna (DOES NOT require external monopole or dipole antenna)
  • Seeker Lite² Charger
  • Carrying Case with Holster (CC-22)
  • Operation Manual on CD

The Seeker Lite² is a Cable TV (catv) leakage detector for cable installations in the field.

  • Numerical Measurement Display
  • Sensitive, Stable Measurements
  • Directional for Leak Location
  • Stable, repeatable readings and built in directional antenna simplify leak location.
  • "Cruise Mode" offers continuous surveillance for long periods at reduced battery current.
  • Tough, simple to use and very cost-effective, the Seeker Lite² is the ideal leakage measurement instrument for insuring leakage -and ingress- free installations, every time.

Seeker Lite² - Installation Leakage Detector

The new Trilithic Seeker Lite² Leakage Detector is specifically designed for efficient subscriber installations, displaying numerical measurements of leaks on up to ten user selectable presets and emitting a tone proportional to leak strength.

Specifications

Frequency Range
118.5 to 147.25 MHz settable using PC configuration software.
Default Frequency Settings:
121.2625 MHz 127.2625 MHz
133.2626 MHz 139.25 MHz 146.2625 MHz
Frequency Setting Range:
Up to ten operating frequencies, selectable by tabbing.
Selections loaded into detector using Seeker Setup PC configuration software.
Level Range: 10 to 2000 μV/M. Can freeze current numeric reading.
Numerical Display:
Readout of any detected leakage within sensitivity range.
Audible Tone:
Tone is present if leakage amplitude exceeds squelch setting.
Pitch is proportional to strength of leak.

 

Accessories

  • Seeker Lite² PC Data Cable (I/O-17)

    Product Image

    Data cable for the Seeker Lite². Used to connect to a PC using the Seeker Setup Software.

  • Seeker Lite² Vehicle Power Adaptor (CL-8)

    Product Image

    Vehicle power adaptor for the Seeker Lite².

  • International Power Adaptor Kit for the Seeker Lite, Seeker Lite² & Seeker

    Product Image

    International power adaptor kit for the Seeker Lite, Seeker Lite² & Seeker Leakage Detectors that includes power adaptors for the UK, Europe and Australia. The Seeker Lite, Seeker LIte² or Seeker Charger is required to use this kit.

Replacement Parts

  • Seeker Lite, Seeker Lite², & Seeker Battery

    Product Image

    Li-ION battery for the Seeker Lite, Seeker Lite², & Seeker Leakage Detectors.

  • Seeker Lite² Charger

    Product Image

    AC to DC power adaptor & battery charger for the Seeker Lite².

  • Carrying case with holster for the Seeker Lite & Seeker Lite² (CC-22)

    Product Image

    Carrying case with holster for the Seeker Lite & Seeker Lite².

Software

  • Seeker Setup Software

    Product Image

    Configures the Seeker and Seeker Lite² Leakage Detectors, enabling operator to assemble files containing Channel Frequencies, Squelch Levels, Audio Volume and other settings. The operator can efficiently download configurations to one or more leakage detectors. The software includes the Seeker & Seeker MCA Mini USB Charge/Data Cable (I/O-20) and Seeker Lite² Data Cable (I/O-17). Includes capability to assemble Seeker GPS leakage data files in a format compatible with the CLT APLAS3i service and to forward the records to the APLAS3i server for analysis and work order generation.

Related Items

  • CT-2

    Product Image

    Hides a distinctive marker signal in the system video carrier used for leakage testing, making it easy to identify the source of signal leakage in “overbuilt” areas.

    The CT-2 comes with standard tagging frequencies of 3 Hz and 20 Hz.  The 20 Hz tagging frequency is adjustable between 10 Hz and 23 Hz.  When ordering, specify your desired tagging frequency. Only one CT-2 is needed per head-end.

     

  • CT-2 (CE Approved)

    Product Image

    This CE Approved version of the CT-2 hides a distinctive marker signal in the system video carrier used for leakage testing, making it easy to identify the source of signal leakage in “overbuilt” areas.

    The CT-2 comes with standard tagging frequencies of 3 Hz and 20 Hz.  The 20 Hz tagging frequency is adjustable between 10 Hz and 23 Hz.  When ordering, specify your desired tagging frequency. Only one CT-2 is needed per head-end.

  • CT-3

    Product Image

    Provides a narrow band, AM modulated carrier that is “tagged” for leakage testing, making it easy to identify the source of signal leakage in “overbuilt” areas.

    When ordering, specify the AM modulated carrier frequency from 108 Mhz to 157 MHz. The CT-3 comes with standard tagging frequencies of 3 Hz and 20 Hz.  The 20 Hz tagging frequency is adjustable between 10 Hz and 23 Hz.  When ordering, specify your desired tagging frequency. Only one CT-3 is needed per head-end.

  • CT-3 (CE Approved)

    Product Image

    This CE Approved version of the CT-3 provides a narrow band, AM modulated carrier that is “tagged” for leakage testing, making it easy to identify the source of signal leakage in “overbuilt” areas.

    When ordering, specify the AM modulated carrier frequency from 108 Mhz to 157 MHz. The CT-3 comes with standard tagging frequencies of 3 Hz and 20 Hz.  The 20 Hz tagging frequency is adjustable between 10 Hz and 23 Hz.  When ordering, specify your desired tagging frequency. Only one CT-3 is needed per head-end.

Firmware

 

Get Updates in your Inbox

Enter your email address to receive alerts when new firmware or application notes are released for the Seeker family.

Posted December 2007

Listed below is the most recent update available for the Seeker Lite² Instrument Firmware. For assistance with any installation, please call tech support at 1-800-344-2412.

Trilithic encourages maintaining up-to-date firmware; however, your company may have policies in place to manage the update process.

WARNING! This firmware is appropriate for most users, but some MSO’s do have different update policies in place. As such, in some cases the standard firmware may render certain test functions inoperable. Please contact your manager before updating your firmware.

Download Now

Please review the updated enhancements below BEFORE installing your Seeker Lite update.

  • Extended Frequency range down to 118.5 MHz (Requires current Seeker Setup to use new range).

Seeker Lite² Firmware Update History

Warranty

Repairs

All repairs carry a 90-day warranty against defects in replacement parts and repair workmanship.

Products

All Trilithic products are warranted against defects in materials or workmanship for a minimum of one year after shipment.

Trilithic's obligation under this warranty is limited to the repair or replacement of the product after being returned to our factory, and Trilithic determining the product be indeed defective.

This is Trilithic's sole warranty and is given in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose and sets forth the buyers sole remedy.

The following products carry a Manufacturers One Year Warranty

8821Q, 8821Q-R & 8853Q Rotary & Benchtop Attenuators TFS-3200 Series
APSS-1B TFS-201 TFS-FS1
DCVF-5 TFS-290 Series TFS-FS1K500 Series
Impedance Matching Pads TFS-301 TLB-60
I-Stop TFS-401 Tunable Filters
Programmable RF Switches TFS-2000 Series VF-4 & VF-5

The following products carry a Manufacturers Two Year Warranty

860 DSP & 860 DSPi 9581 SST R3 & 9581 SST R4 RSVP²
860 DSPh & Input Expander 9581 TPX Seeker Lite²
860 DSPr CT-2/ CT-3 Seeker
8300 FST Model Two Seeker MCA
8310 RSA Model Three Seeker BB-2

The following products carry a Dell Three Year Warranty

All Specially Configured Dell PowerEdge 2U Rack Mount Server products are warranted against defects in materials or workmanship for a minimum of three years after shipment. Dell provides next business day, parts and labor, on-site response for the following Trilithic products.

ADIA Integrated Server Package LAW Server Package
Guardian II Integrated Server Package Trilithic Data Manager (TDM) Integrated Server Package

 

Think Ahead.
Copyright © 2010 Trilithic, Inc. All Rights Reserved
Execution time: 0.18 seconds
Close

Translate Page

  • To translate page from English to another language, select a language from the drop-down list.
  • To return the page to English, click the Show Original button in the Google Translate bar at the top of the page.
  • To close Google Translate, click the X in the Google Translate bar at the top of the page. This also changes the page back to English.
  • To close this dialogue, click the Close button.
Notice: Translations are approximate.
Close

Session Alert

Notice: Your session is about to expire. If you would like to continue, please click the Continue button. Otherwise you will be logged out and must log back in to return to the current page.

Sign In

My email address is *
* You may also enter your Trilithic screen name.